Acoustic Absorption Element AKE 41 AG/IG
1 Variant
Universally applicable sound absorption element for higher loads. Suitable for soundproof installation according to DIN 4109. Especially suitable for sound isolation of constructions made of Channels 41 or electrical equipment, e.g. pumps or ventilators.

Anti-Vibration Element GMT
1 Variant
The Rubber-Metal Combination Element GMT suppresses vibrations originating from various systems. Such vibrations generated by the system (such as motors, boilers..) are normally transmitted as sound to the environment via rigid building structures. The mounting situation does not affect the efficiency of the Sikla Rubber-Metal Combination Element GMT, this element may also be applied as a horizontal stop buffer.

Axial Stop AS HCP
5 Variants
Modification of Simotec pipe shoes to a single-sided axial stop, for use with traditional steel beams. Using the Axial stop, the pipe shoe can move axially through the pipe to a predefined degree of displacement, with restricted limits in one axial direction.

Axial Stop Variable VAS HCP
3 Variants
Modification of siMotec pipe shoes to a double-sided variable axial stop, for use with traditional steel beams. Using the Axial stop, the pipe shoe can move axially through the pipe to a predefined degree of displacement, with restricted limits in both axial directions.

Beam Connection LKA-A/B HCP
12 Variants
Connecting assembly for the direct attachment of rod hanger assemblies to beam sections with a flange width 100-310mm. The pre-welded Eye-Plate which is fastened to the siFramo80/30 section serves as a basic element for the connection of the Rod Hanger Load Chain Assembly LKV in sizes M10 up to M16 rod and Pipe Clamps type Stabil Form C LK.

Brace Joint SG
3 Variants
The Support Joint is fixed directly to the flanges of the pipe clamp to provide additional bracing to the overall pipe support. Adjustable brace angle. The Support Joint can be rotated 180° radially about the clamping bolt connections either side of the pipe clamp. Captive pivoting link eye.

Bracket for vertical pipes SFK
1 Variant
The Flange Clamp Fit SFK can be used for downpipes ranging from DN 100 to DN 150 thanks to its flexible adjustment options – one bracket for three sizes! Preferably used in combination with Pipe Clamp Stabil D-A or, if sound absorption is required, with Stabil D-A with Lining (see below). Adjustable in two horizontal directions, thus ensuring an exact and tension-free run of vertical pipes. In case SFK Brackets from pipe manufactures are used, rubber rings are added as insulation.

Cable Holder KHP
1 Variant
Clip for connecting cables up to a diameter of 16mm to PV mounting systems. Suitable to slot into the back of all Channels MS 41 with min. profile thickness of 2mm.

Cellular Rubber Lining MSK
5 Variants
Sound absorption lining for steel straps and pipe clamps.

Chilled Water Clamp AKS 13
13 Variants
Suitable for secure prevention of condensation at the pipe support location of chilled-water and cold-water pipelines as well as insulation clamp for heating systems. Suitable for soundproof installation according to DIN 4109.

Chilled Water Clamp AKS 19
13 Variants
Suitable for secure prevention of condensation at the pipe support location of chilled-water and cold-water pipelines as well as insulation clamp for heating systems. Suitable for soundproof installation according to DIN 4109.

Chilled Water Clamp AKS 25
13 Variants
Suitable for secure prevention of condensation at the pipe support location of chilled-water and cold-water pipelines as well as insulation clamp for heating systems. Suitable for soundproof installation according to DIN 4109.

Chilled Water Clamp KS RB
23 Variants
Insulated pipe clamp made of PUR-foam for chiller plants and cool water systems.

Chilled Water Clamp LKS 13
36 Variants
Suitable for secure prevention of condensation water at the pipe support location of refrigeration and cold-water pipelines. An optimal diffusion-tight connection with the pipe insulation is easily and safely achieved by fixing usual insulation materials to the clamp faces using adhesive. Recommended up to -0°C at normal ambient condition.

Chilled Water Clamp LKS 19
40 Variants
Suitable for secure prevention of condensation water at the pipe support location of refrigeration and cold-water pipelines. An optimal diffusion-tight connection with the pipe insulation is easily and safely achieved by fixing usual insulation materials to the clamp faces using adhesive. Recommended up to -0°C at normal ambient condition.

Chilled Water Clamp LKS 32
27 Variants
Suitable for secure prevention of condensation water at the pipe support location of refrigeration and cold-water pipelines. An optimal diffusion-tight connection with the pipe insulation is easily and safely achieved by fixing usual insulation materials to the clamp faces using adhesive. Recommended up to -0°C at normal ambient condition.

Chilled Water Clamp SKS Top-2C
22 Variants
Used for cold-water pipeline systems and refrigeration installations. Fixation of pipe lines degenerated from sound and vibration. First class sound absorption by means of soft foam. One size covers several pipe dimensions. Permissible pipe dia. tolerances are securely adjusted by the elastomer part which also prevents from condensation which may occur due to slots. No sealant is needed - the smooth adhesion of the pipe insulation at the front surface is possible. Suitable also for heavy loads.

Chilled Water Fixed Point Clamp FKS
10 Variants
Fixed Point Chilled Water Clamp for the absorption of axial forces. Especially used for risers. The contraction forces are transferred to the pipe clamp by a steel pressure ring welded to the perimeter of the steel pipe. The clamp is anchored to the building structure via an installed anchor bracket.

Clamping Set SPZ HCP
3 Variants
Clamping Set for construction of bracings and wind bracings e.g. in the system siFramo as tie rod to transfer loads/influences.

Ducting Angle LUW A-L
1 Variant
Mounting Angle for rectangular ducts installed directly under the ceiling, or for suspended installation when using a threaded rod.

Ducting Angle LUW A-SL
1 Variant
Mounting Angle for rectangular ducts installed directly under the ceiling, or for suspended installation when using a threaded rod. Types A-SL and A-SZ allow for soundproof installation also according to DIN 4109.

Ducting Angle LUW A-SZ
1 Variant
Mounting Angle for rectangular ducts installed directly under the ceiling, or for suspended installation when using a threaded rod. Types A-SL and A-SZ allow for soundproof installation also according to DIN 4109.

Ducting Angle LUW A-Z
1 Variant
Mounting Angle for rectangular ducts installed directly under the ceiling, or for suspended installation when using a threaded rod.

Ducting Angle LUW F
1 Variant
Ducting Angle for a direct installation to the flange of rectangular ventilation ducts. Due to this external connection it's not necessary to penetrate the duct, therefore flow losses do not occur. In addition there are no leakages and flow noises. No disturbing screw tips interfere with cleaning operations. The Ductings Angles LUW F exceed the demands of VDI Standard 6022 (Hygiene requriements for ductings). Type LUW SF is suitable for soundproof duct installations according to DIN 4109. The slot allows adjustment facilities to compensate drill hole differences and construction tolerances.