Choose your country
Go to your local Sikla page and discover offers for your country or sales region:
Country
WBD-P F 100 - 201/310




Group: A821
Part number 117169
Plug-in component for creating a square end plate at the open end of Beam Section TP F 100 or Beam Bracket/Cantilever Bracket AK F 100
Variation 'T' with octagonal insert allows full utilisation of the beam section within the space required by the End Support WBD

BP | 420 mm |
BP1 | 275 mm |
bP | 18 mm |
HP | 220 mm |
HP1 | 160 mm |
LG | 233 mm |
tP | 12 mm |
TP1 | 27 mm |
-VX,perm. | 64,00 kN |
VX,perm. | 64,00 kN |
-VY,perm. | 115,60 kN |
VY,perm. | 115,60 kN |
-VZ,perm. | 126,50 kN |
VZ,perm. | 126,50 kN |
-MX,perm. | 6,2 kNm |
MX,perm. | 6,2 kNm |
-MY,perm. | 5,7 kNm |
MY,perm. | 5,70 kNm |
-MZ,perm. | 6,4 kNm |
MZ,perm. | 6,4 kNm |
Material base body | steel |
Surface | HCP |
Corossion class | C4 |
Also available with DUALSHIELD for high corrosion protection within C5H environments.
Certification

CE mark (Declaration of performance see downloads)
ETA-24/0471
Depending on the situation, different options are recommended:
Types F100:
a) Directly to building structure: 4 x suitable wall anchors and 4 Self Forming Screws FLS applied to the square/octagonal insert
b) To traditional steel beams between 80 – 310 mm flange dimensions: 1x Assembly Set 5P M12 S, M16 S and 4 Self Forming Screws FLS applied to the square/octagonal insert
c)To Sikla Simotec steel beams 100/120: with Bracket Plates FV 100/120 when positive mechanical connection required
The Beam Section TP F 100 connected to the End Support WBD F 100 has to be screwed with 4 Self Forming Screws FLS F. On each of the opposite sides 2 Self Forming Screws FLS F are necessary. The permissible distance between base plate WBD and profile must not exceed 30 mm.
Types 100/160
a) Directly to building structure: 4 x suitable wall anchors and 4 Self Forming Screws FLS applied to the square/octagonal insert.
b) To traditional steel beams between 80 – 300 mm flange dimensions: 1x Assembly Set 5P M12 S, M16 S and 4 Self Forming Screws FLS applied to the square/octagonal insert.
The Beam Section TP F 100/160 connected to the End Support WBD F 100/160 has to be screwed with 8 Self Forming Screws FLS F. On each of the broader sides 4 Self Forming Screws FLS F are necessary.
Base plate finish:
| Type | Base plate finish |
|---|---|
| WBD F 100-80/120 | flat |
| WBD-P F 100-121/160 | corrugated |
| WBD-P F 100-161/200 | corrugated |
| WBD-P F 100-201/310 | corrugated |
| WBD F 100-T | flat |
| WBD F 100/160-121/160 | flat |
| WBD F 100/160-161/200 | flat |
| WBD F 100/160-201/300 | flat |