Group: 1562
Roof Hook for standard tiles and roof batten thickness of 24 resp. 30 mm. To provide a simple direct fixing of Channel 41 to the roof by means of one Self Forming Screw FLS.
Remove roof tiles. Position the hook where the trough of the tile was located. Position the base plate of the Roof Hook in full contact with the rafter. Falls erforderlich, müssen Hilfslatten zur Dachmontage eingesetzt werden. Pre-drill 7 mm holes into the rafter and fix it with a minimum of two Hexagon Wood Screws 10 x 100. Clear removed tiles from the respective area and put them back to their original position. Fix the Channel onto the Roof Hook through the slotted rear face of the profile with one Self Forming Screw. For roof structures > 50 mm the Roof Hook could be shimed. Roof Hooks for special tiles /profiles on request. In order to preserve the balanced loading of the roof we recommend this application to all rafters.
Max. perm. loads:
| Type | Fz [kN] | Fq [kN] |
|---|---|---|
| DH fix-40/8 | 2.5 | 1.25 |
| DH fix-45/5 | 1.2 | 0.75 |
| DH fix-45/8 | 2.5 | 1.25 |
| DH fix-50/8 | 2.5 | 1.25 |
| Material: | Steel, HCP or HDG |
| Type | H1 [mm] |
H2 [mm] |
L1 [mm] |
L2 [mm] |
W [kg] |
Quantity/ [pack] |
Part number |
|---|---|---|---|---|---|---|---|
| DH fix-40/8 | 40 | 85 | 105 | 65 | 1.00 | 1 | 110002 |
| DH fix-45/5 | 45 | 80 | 105 | 65 | 0.91 | 1 | 194072 |
| DH fix-45/8 | 45 | 80 | 105 | 65 | 1.01 | 1 | 196762 |
| DH fix-50/8 | 50 | 80 | 105 | 65 | 1.10 | 1 | 111444 |