Group: 1406
Suitable for push-through mounting solutions for quick and safe fixation to concrete ceilings or walls in closed rooms - not suitable for damp locations.
Setting Tool PN is most suited for mounting purposes.
| Permissible load in the tensile zone [kN] for installation solutions in concrete ≥ B25 acc. to approval) | 1,1 |
| Centre distance a ≥ [mm] | 130 |
| Edge distance ar ≥ [mm] | 100 |
| Minimum thickness of component d [mm] | 80 |
| Diameter of drill d0 [mm] | 6 |
| Depth of bore hole h0 ≥ [mm] | 40 |
| Anchoring depth hef ≥ [mm] | 32 |
| Material: | Steel, electro-galvanised |
ETA-Approval: ETA-06/0259
Approved in the tensile zone for multiple mounting solutions to concrete exposed to mainly dead static loading.
Permissile load fire resistance:
| 30 min. N(30) | = | 0,45 kN |
| 60 min. N(60) | = | 0,35 kN |
| 90 min. N(90) | = | 0,25 kN |
| 120 min. N(120) | = | 0,20 kN |
R30 to R120
| Centre distance a ≥ [mm] | 200 |
| Edge distance ar ≥ [mm] | 150 |
| Type | Length of dowel [mm] |
Max. eff. length da [mm] |
Bore depth when push-through mount. td [mm] |
W [kg] |
Quantity/ [pack] |
Part number |
|---|---|---|---|---|---|---|
| PN 27 N6 x 35 | 39 | 4.5 | 40 | 0.01 | 100 | 196298 |