Group: 1409
Threaded stud for put-before mounting to be used with injection system VMU and injection adhesive VM-K. For anchoring in concrete tensile pressure zones or in brickwork. Suitable for attaching pipelines, channels, brackets, etc. in closed rooms - except for damp locations (stainless steel version available on request).
Pre-assembled with washer and hexagon nut.
| 1. | Drill hole according to min. setting depth vertically to the surface |
| 2. | Careful cleaning of drill hole with steel brush and blow-out pump |
| 3. | Screw mixing nozzle onto the cartridge; foreshots to be removed and fill 2/3 of drill hole with resin starting from botton of the hole. |
| 4. | Drive the anchor manually into plastered borehole up to its embedment mark |
| 5. | When reaching the embedment mark, plaster must be apparent. |
| 6. | Respect hardening time, when tighten the anchor with instructed torque |
Detailed assembly instruction is attached to the product.
| Material: | Steel, galvanised |
| Type | Total length [mm] |
tfix = Max. effective length [mm] |
W [kg] |
Quantity [pack] |
Part number |
|---|---|---|---|---|---|
| VMU-A 8-20/110 | 110 | 20 | 0.05 | 10 | 110444 |
| VMU-A 8-55/145 | 145 | 55 | 0.06 | 10 | 110445 |
| VMU-A 10-30/130 | 130 | 30 | 0.09 | 10 | 110447 |
| VMU-A 10-50/150 | 150 | 50 | 0.10 | 10 | 110448 |
| VMU-A 12-15/120 | 120 | 15 | 0.14 | 10 | 110449 |
| VMU-A 12-50/155 | 155 | 50 | 0.14 | 10 | 110450 |
| VMU-A 16-15/160 | 160 | 15 | 0.27 | 10 | 110451 |