Products

Search

Anchors and Small Parts

Drop-In Anchor AN ES new

page as pdf page as pdf

Group: 1401

Application

Drop-in Anchor for non-cracked concrete and multiple use in cracked concrete.
Suitable for fixing pipelines, channels, etc. meeting the respective approval requirements - for damp locations and outdoor constructions the stainless steel version is required.

  • No special drill required
  • Setting tool for distance-controlled forced expansion
  • Suitable for push-through mounting

Installation

As expansion tool use the respective expansion cone for Drop-In Anchor.
The "intelligent" expansion cone facilitates the mounting with bore dia. tolerances or varying concrete quality. By the controlled deformation of the cone during installation, the needed edge and centre distances are decreasing considerably.

Technical Data

General loads and performance data:

Anchor size
M8x30
M8x40
M10x30
M10x40
M12
Nominal drill hole diameter d0 = [mm] 10 10 12 12 15
Depth of drill hole h0 = [mm] 30 40 30 40 50
Installation torque Tinst = [Nm] 8 8 15 15 35
Diameter of clearance hole in the connecting
element df ≤ [mm]
9 9 12 12 14
Maximun screwing depth Lth [mm] 13 20 12 15 18
Minimum screwing depth Lsdmin [mm] 9 9 10 11 13
Minimum thickness of concrete slab hmin [mm] 100 100 120 120 130
Minimum centre distance smin [mm] 60 80 100 100 120
Minimum edge distance cmin [mm] 95 95 135 135 165


Extract from Permissible Service Conditions of ETA-10/0258 cracked-concrete / Multiple use for nonstructural applications:

Anchor size
M8x30
M8x40
M10x30
M10x40
M12
Approved loads for C20/25-C50/60 [kN] 1.7 2.0 2.0 2.0 2.4
Approved bending moments (Steel 4.6) Mperm [Nm] 6.4 6.4 12.8 12.8 22.2
Approved bending moments (Steel 8.8) Mperm [Nm] 17.1 17.1 34.3 34.3 60.0
Characteristic centre distance scr [mm] 180 210 230 170 170
Characteristic edge distance ccr [mm] 90 105 115 85 85
Loads under fire exposure Steel 4.6  
Approved loads R30 perm. F [kN] 0.4 0.4 0.9 0.9 1.7
Approved loads R60 perm. F [kN] 0.3 0.3 0.8 0.8 1.3
Approved loads R90 perm. F [kN] 0.3 0.3 0.6 0.6 1.1
Approved loads R120 perm. F [kN] 0.2 0.2 0.5 0.5 0.8
Loads under fire exposure Steel ≥ 5.6  
Approved loads R30 perm. F [kN] 0.9 0.9 1.5 1.5 1.7
Approved loads R60 perm. F [kN] 0.9 0.9 1.5 1.5 1.5
Approved loads R90 perm. F [kN] 0.9 0.9 1.5 1.5 1.5
Approved loads R120 perm. F [kN] 0.4 0.4 1.0 1.0 1.2


Extract from Permissible Service Conditions ETA-10/0257 non-cracked concrete:

Anchor size
M8x30
M8x40
M10x30
M10x40
M12
Approved tensile load C20/25 (Stahl 4.6 to 8.8) [kN] 2.8 3.6 4.0 5.1 7.1
Oblique (Steel 4.6) perm. V ≥ C20/25 [kN] 3.1 3.1 3.7 4.1 7.2
Oblique (Steel 8.8) perm. V ≥ C20/25 [kN] 3.9 3.9 3.7 4.1 12.0
Bending moments (Screw 4.6) perm. M [Nm] 6.4 6.4 12.8 12.8 22.2
Bending moments (Screw 8.8) perm. M [Nm] 17.1 17.1 34.3 34.3 60.0


The values of the mentioned approvals in their latest version are valid
- see www.sikla.de/service/downloads.

Material:
Steel, electro-galvanised

Approvals

For multiple use for nonstructural applications Sikla Approval ETA-10/0258 (M8 - M12), for anchorage in non-cracked concrete Sikla Approval ETA-10/0257, Fire protection examination, VdS-conform, FM-Approval ≥ M10

Type Drill hole ø x
depth [mm]
Thread ø x
length [mm]
W
[kg]
Quantity
[pack]
Part
number
ES M8 x 30 10 x 30 M8 x 13 0.01 100 110467
ES M8 x 40 10 x 40 M8 x 20 0.01 100 110468
ES M10 x 30 12 x 30 M10 x 12 0.02 50 110506
ES M10 x 40 12 x 40 M10 x 15 0.02 50 110469
ES M12 x 50 15 x 50 M12 x 18 0.04 50 110470

back to chapter