Products

Search

Anchors and Small Parts

Bolt Anchor AN BZ plus

page as pdf page as pdf

Group: 1408

Application

Anchor for push-through mounting in M&E services and plant construction in concrete tensile zones.
This anchor combines high permissible loads with close edge and centre distances.
Suitable for anchoring in cracked and non-cracked concrete - fixation of pipelines, channels, brackets, etc. in closed rooms - except for damp locations.

  • No special drill required. Bore dia = thread size
  • Simple and quick mounting due to its push-through concept
  • Drive-in hammer zone for preventing any thread damage

Configuration

Supplied with washer and hexagon nut.

Installation

1.
Drill bore hole according to the minimum bore hole depth perpendicularly to the surface.
2.
Remove dirt from hole.
3.
Drive the anchor into concrete up to its embedment mark.
4.
After tightening the anchor with a torque wrench Tinst (see torque indicated in the following tab), it may immediately be submitted to loading.

Note the instructions in the mounting manual!

Technical Data

Type
M8
M10
M12
M16
Perm. load 1) tension C20/25 2) [kN] 2.4 4.3 5.7 11.9
C25/30 2) [kN] 2.6 4.7 6.3 13.1
C30/37 2) [kN] 2.9 5.2 7.0 14.5
C40/50 2) [kN] 3.4 6.0 8.1 16.8
C50/60 2) [kN] 3.7 6.6 8.9 18.5
Perm. load 1) oblique ≥ C20/25 2) [kN] 8.6
(5.0)3) 
12.6
(6.5)3) 
18.0
(8.5)3) 
26.9
(23.6)3)
Perm. bending moment 1) [Nm] 13.1 26.9
(25.7)3) 
46.9
(44.6)3) 
119.4
(99.,9)3)
Min. thickness of component hmin ≥ [mm] 100 120 130 170
( 3 hef ) Charact. centre distance scr [mm] 138 180 195 255
( 1.5 hef ) Charact. edge distance ccr [mm] 69 90 97.5 127.5
Min. centre distance s at/edge distance c ≥ [mm] 40/70 45/70 60/100 60/100
Min. edge distance c at/centre distance s ≥ [mm] 40/80 45/90 60/140 60/180
Effective anchoring depth hef [mm] 46
(35)3) 
60
(42)3) 
65
(50)3) 
85
(64)3)
Nominal diameter of drill d0 [mm] 8 10 12 16
Depth of bore hole h1 ≥ [mm] 60
(55)3) 
75
(65)3) 
90
(75)3) 
110
(95)3)
Anchoring torque Tinst [Nm] 20
(15)3) 
25
(30)3) 
45
(50)4) 
90
(100)3)
Perm. load 4) for fire exposure    
Perm. load R30 perm. F [kN] 1.3 2.2 3.0 6.0
Perm. load R60 perm. F [kN] 1.1 1.8 2.8 5.2
Perm. load R90 perm. F [kN] 0.8 1.4 2.4 4.4
Perm. load R120 perm. F [kN] 0.7 1.2 2.2 4.0


1) Loads for single anchors without influence of edge distances
2) Cracked concrete (option 1)
3) Value in brackets applies for the types marked *
4) Edge/Centre distances in case of fire - respective approval is to be respected

The safety factor according to ETAG is included already. Valid are the values of the mentioned approval which could be seen under www.sikla.de/service/downloads.

Material:
Steel, galvanised

Approvals

Sikla approval ETA-10/0259
FM-approval for M10, M12, M16
VdS-conform for all sizes
Shock approval of the Federal Office for Civil Defence, Bern (Switzerland)



The types marked * are not part of the approvals.

Type Thread
connection
tfix = Max.
effective length
[mm]
Total length
[mm]
W
[kg]
Quantity
[pack]
Part
number
8/5/50 * M8 5 50 0.02 100 110542
8/10/75 M8 10 75 0.03 100 166526
8/30/95 M8 30 95 0.04 100 166535
8/50/115 M8 50 115 0.04 100 110453
8/100/165 M8 100 165 0.06 50 110543
10/10/60 * M10 10 60 0.05 50 110544
10/10/90 M10 10 90 0.06 50 166544
10/20/100 M10 20 100 0.06 50 110545
10/30/110 M10 30 110 0.07 50 166553
10/50/130 M10 50 130 0.08 50 166562
10/75/155 M10 75 155 0.09 50 110546
10/100/180 M10 100 180 0.05 50 110454
12/5/75 * M12 5 75 0.08 25 110547
12/15/110 M12 15 110 0.10 25 166571
12/30/125 M12 30 125 0.11 25 166580
12/50/145 M12 50 145 0.12 25 166599
12/65/160 M12 65 160 0.14 25 110548
12/85/180 M12 85 180 0.15 25 110549
12/105/200 M12 105 200 0.18 25 166605
12/160/255 M12 160 255 0.23 20 166614
16/5/90 * M16 5 90 0.16 20 110550
16/25/145 M16 25 145 0.23 20 166623
16/50/170 M16 50 170 0.26 20 166632
16/100/220 M16 100 220 0.35 10 166641

back to chapter